Model
WZ-360kW
Basic info
Brand RW Energy
Model NO. Liquid-cooled fast charging station
Rated Output Rating 360KW
Output Voltage DC 200-1000V
Max Output Current 200A
Power Conversion Efficiency ≥95%
Connector Options GBT+GBT
Cable Length 5m
Input Voltage 380V
Series DC EV Chargers
Product Detail

Description:

This 360kW liquid-cooled ultra charging station adopts industry-leading direct liquid-cooling technology, designed for next-generation EVs to deliver extreme fast charging experience. With a maximum single-gun power of 360kW and an intelligent thermal management system, it charges vehicles from 10% to 80% in just 15 minutes—revolutionizing traditional charging efficiency. The station is compatible with global mainstream charging protocols (CCS1/CCS2, CHAdeMO, GBT) and supports dynamic power allocation, enabling simultaneous high-efficiency charging for two vehicles in dual-gun mode.

Features:

  • High power output: Due to the effective heat dissipation of liquid cooling technology, liquid-cooled fast charging stations can support higher power charging outputs, allowing electric vehicles to charge to more than 80% of their capacity in a short period of time.

  • Extended equipment life: Effective temperature management can reduce the thermal stress on power electronic devices, extending their service life.

  • Improved charging efficiency: The liquid cooling system can maintain the battery within the optimal temperature range, thereby increasing charging efficiency.

  • Reduced noise: Compared to air-cooling systems, liquid cooling systems operate with lower noise, making them more suitable for installation in environments sensitive to noise.

  • Strong adaptability: Liquid cooling technology is less affected by ambient temperatures and can maintain good heat dissipation effects even under extreme weather conditions.

Technical Parameters:

Product Number

WZ-360kW

Input

400VAC / 480VAC (3P+N+PE) || 50/60Hz

Output Voltage

200 - 1000VDC

Output current

0 to 1200A

Parallel Charge Mode (Optional)

30 kW per Port

Efficiency

≥94% at nominal output power

Power factor

>0.98

Operating temperature

-30°C to 55°C

Altitude

< 2000m

Working || Storage Humidity

≤ 95% RH || ≤ 99% RH (Non-condensing)

Display

7’’ LCD with touch screen

Dimensions (L x D x H)

1200mm x 500mm x 1700mm

Ingress Protection

IP54 || IK10

Power Electronics Cooling

Air Cooled

Weight

550kg

Insulation (input - output)

>2.5kV

Regulatory Compliance

CE || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012

Charging Protocol Standards

Mode 4 - IEC-61851, ISO-15118, DIN 70121 Mode 4 - GB/T 18487 2023, GB/T 20234 2023, GB/T 27930 2023

Length of charging cable

5m

Communication protocol

OCPP 1.6J

Communication

Ethernet – Standard || 3G/4G Modem (Optional)

Electrical Safety: GFCI

RCD 30 mA Type A

Electrical Safety: Surge Protection

20 kA

Electrical Safety General

Over Voltage, Under Voltage, Over Current, Missing Ground

Electrical Safety: Output Short

Output power disabled when output is short circuited

Electrical Safety Temperature

Temperature Sensors @ Charge Coupler and Power Electronics

Emergency Stop

Emergency Stop Button Disables Output Power

Dual-gun Charging terminal:

Product Number

WZ-200A

Output Voltage

200 - 1000VDC

Output current

0 to 400A

Connectors

CCS2 || GBT

*Single and Dual

Single-gun charging mode

CCS2 –200A || GBT- 200A

Operating temperature

-30°C to 55°C

Altitude

< 2000m

Working || Storage Humidity

≤ 95% RH || ≤ 99% RH (Non-condensing)

Dimensions (L x D x H)

500mm x 300mm x 1700mm

Ingress Protection

IP54 || IK10

Power Electronics Cooling

Natural cooling

Weight

100kg

Regulatory Compliance

CE || EMC: EN 61000-6-1:2007, EN 61000-6-3:2007/A1:2011/AC:2012

Charging Protocol Standards

Mode 4 - IEC-61851, ISO-15118, DIN 70121 GB/T 18487 2023, GB/T 20234 2023, GB/T 27930 2023

Length of charging cable

5m

Communication protocol

OCPP 1.6J

Liquid-cooled fast charging has the following advantages:
Charging speed aspect
Strong current-carrying capacity and fast charging speed: It can effectively cool the interior of the charging gun and can withstand higher currents without overheating. Compared to traditional charging methods, it can achieve greater charging current and power, greatly shortening the charging time. For example, currently, the power of ordinary fast charging piles is generally around 120kW. Conventional supercharging piles are around 300kW. Some liquid-cooled supercharging piles can reach a maximum power of up to 600kW, such as the fully liquid-cooled supercharging piles of Huawei and NIO.
It solves the problem of cable overheating during high-current charging. There is no need to increase the cross-sectional area of the wire to reduce heat generation, making the charging equipment lighter and ensuring high-current transmission at the same time.

Safety performance aspect
Fast heat dissipation and good temperature control: It uses liquid circulation to take away the heat generated by the battery and charging equipment during the charging process, making the battery temperature more uniform, avoiding local overheating, reducing the risk of battery thermal runaway, and prolonging the battery's service life.
The thermal conductivity coefficient of the coolant is dozens of times that of air. The heat dissipation capacity of the liquid-cooled module can be reduced by 10 - 20°C compared to the air-cooled module, which can significantly improve the cooling efficiency and reduce the corrosion and damage to the charging equipment.
High protection level: The fully liquid-cooled method can achieve full coverage, improving insulation and safety. It can make the charging pile reach a relatively high-level dustproof and waterproof performance of about IP65 of international electrical standards, reducing the impact of external factors such as dust and moisture on the internal electrical components of the equipment and improving the reliability and stability of the equipment.

Multiple safety guarantees: Usually equipped with multiple safety guarantee functions such as overheat protection, overcurrent protection, and short-circuit protection. The intelligent control system can also monitor the battery's temperature and charging status in real time and intelligently adjust the charging current and voltage according to the actual situation to ensure the user's safety of use to the greatest extent.
Usage experience aspect
Light charging gun cable: Due to solving the heat dissipation problem, liquid-cooled supercharging piles can use cables with a smaller cross-sectional area to ensure the transmission of greater currents. Therefore, its cables are thinner and lighter than those of conventional supercharging piles, and the charging gun is also lighter. It is more convenient for users to use, especially for people with less strength such as female car owners.
Low noise: Fully liquid-cooled charging piles adopt a double-cycle heat dissipation structure. The internal liquid-cooled module dissipates heat by driving the coolant circulation through a water pump. The external part uses a large fan or air conditioning system with low speed but high air volume to effectively dissipate the heat on the radiator. Compared with the high-speed small fan of traditional air-cooled charging piles, the noise interference is smaller. It can be reduced from about 70 decibels of air-cooled charging piles to about 30 decibels, close to the sound of a whisper, avoiding the problem of being complained about due to large noise at night in places such as residential areas.
Economic cost aspect
Long equipment life and reduced total life cycle cost (TCO): Traditional charging piles using air-cooled charging modules usually have a service life of no more than 5 years. While the service life of fully liquid-cooled charging piles can generally reach more than 10 years. For example, the designed service life of Huawei's fully liquid-cooled supercharging pile is more than 15 years, which can cover the entire life cycle of the station, reducing the cost of replacing equipment during the operation of the charging station. Moreover, fully liquid-cooled charging piles only need to be rinsed after dust accumulates on the external radiator. The maintenance is simple. Compared with air-cooled module charging piles that need to open the cabinet frequently to remove dust and perform maintenance operations, a lot of maintenance costs are saved. In general, its total life cycle cost is lower than that of traditional air-cooled charging equipment. With the wide and mass application of the fully liquid-cooled system, the cost-performance advantage will be more obvious.

How does a liquid-cooled fast charging station work?

A liquid-cooled fast charging station refers to a charging facility that uses liquids (usually coolants with good thermal conductivity, such as water-based coolants or special coolants) to dissipate heat during the charging process. This technology can effectively remove the heat generated during charging, ensuring that the charging equipment and electric vehicle batteries operate within an appropriate temperature range.


Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High Voltage Electrical Apparatus/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Related Products
Related Knowledges
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
A hybrid DC circuit breaker
A hybrid DC circuit breaker
Most DC molded-case circuit breakers use natural air arc extinction, and there are typically two arc extinguishing methods: one is conventional opening and closing, where the contacts axially stretch the arc, while the conductive circuit generates a magnetic field that bends and elongates the arc, pulling it lengthwise perpendicular to the arc axis. This not only increases the arc length but also induces lateral motion, enabling air cooling to achieve arc extinction.The other method involves the
Echo
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!